You want to reduce your energy costs but you need reliable sample cooling?
The Eppendorf CryoCube F570 series of ULT freezers minimizes operating costs while providing superior protection for your critical samples. A combined insulation based on vacuum insulation panels and polyurethane foam enables extremely low energy consumption. The CryoCube F570h needs 14 % less energy than its predecessor. More information

.
.

Product Information

The Eppendorf CryoCube F570 series offers a 5-compartment lay-out and 5 inner doors for easy sample access.

The series is based on three models:
› CryoCube F570: 130 mm wall based on polyurethane insulation, "classic" cooling liquids, air-cooling
› CryoCube F570h: 130 mm wall based on polyurethane insulation and vacuum insulation panels, "green" cooling liquids (R290/ R170), air-cooling
› CryoCube F570hw: 130 mm wall based on polyurethane insulation and vacuum insulation panels, "green" cooling liquids (R290/ R170), water-cooling

The CryoCube F570 has a volume of 570 L (20.1 square feet) and a temperature range from -50 °C to -86 °C.

PhysioCare
Besides sustainability, the main focus of our freezers is on ergonomic aspects. Especially the new door handle of the CryoCube models is based on the Eppendorf PhysioCare Concept: Safe grip but very light forces needed to open and close the freezer door. The interface is on eye level for easy reading of all settings. The automatic vent port enables fast re-access to your samples.


Cost of ownership
When investing in a new ULT freezer, the product price itself is only one aspect. Others include the long-term costs of power consumption and the costs of service and spare parts. Keep in mind, a high-quality ULT freezer will do its job in the lab for 10 years or more.


Sample safety
The CryoCube F570 series is equipped with reliable heavy-duty compressors (2-stage cascade cooling system). Quick pull-down times enable fast re-use after cleaning/defrosting of the instrument. The freezers have short recovery times after opening to provide extra sample safety.
Their temperature range is from -50 °C to -86 °C.
For even higher sample safety, the ULT freezers can be equipped with CO2/LN2 back-up systems and a chart recorder. Temperature monitor systems can be used to monitor the freezers remotely.


Sustainability
Sustainability for ULT freezers is a challenge: Maintaining extremely low temperatures of -86 °C for 24 hours a day, 7 days a week needs energy.
By following the epGreen concept, the Eppendorf freezer R&D team developed intelligent solutions where energy savings are combined with durable long-lasting product quality and ergonomic aspects. By using highly efficient technologies, the CryoCube F570h just needs 7.6 KWh/day. This future-oriented instrument class provides consumption levels which are ahead of most competitors within this volume class. The CryoCube F570h (115 V) is certified by ENERGY STAR®.

Support the epGreen initiative with your Eppendorf ULT freezer


Eppendorf Ultra-Low Temperature freezers are among the most energy-efficient in the industry, reducing energy consumption by thousands of kilowatt hours over our competition.

Hydrocarbons
In 2014, the European Union announced a ban of all non-hydrocarbon-liquids (EU_517/2014) until 2020.
Hydrocarbons are also known as green or natural gases. The two major representatives are propane and ethane (known as R290 and R170). Based on IEC 60335-2-89, there are no additional safety instructions for using green gases in ULT freezers necessary.
This ban includes all cooling devices except instruments for temperatures below -50°C. Based on this exception, ULT freezers of -86°C can continue to run with HFCs. Still, it makes sense to replace the HFC cooling liquids also for ULTs as global warming needs to be slowed down.
Due to this goal, we at Eppendorf clearly plan to replace all classic cooling ULT freezers within the next years.

Remember 2008?
As being on of the very first movers for green gases at -86°C, Eppendorf has now 10 years of experience in R&D, production, logistics, and service in the field.
In 2008, the (Eppendorf) New Brunswick Premium U570h was one of the very first commercially available ULT freezers driven by green cooling liquids.


Factors influencing the energy consumption
› Thickness of insulation
› Type of insulation
› Type of cooling liquid
› Efficiency of compressors
› Control of compressor
› Pressure in cooling system
› Style of cooling loops (diameter, length, density,..)
› Sealings of outer door
› Sealings of inner doors
› Insulation of inner doors
› Insulatioon of outer door


Our part for sustainability
› Production moved into new building with state-of-the-art building insulation to save heating energy and power
› Heat output during final individual unit testing discharges building heating system
› Plastic and cardboard compactors introduced + waste rebate system in place
› Local requirements for waste management (collection of electronic waste like circuit boards, recycling via authorized recycling organizations) and internal guide lines
› Usage of green cooling liquids in Eppendorf ULT freezers for 10 years
› Packaging parts have increasing share of recycled origin
› Packaging is more than 99% recycable (wood, cardboard, PE-foil)
› REACH + RoHS compliant
› ENERGY STAR® partner
› Marketing material is printed on FSC certified paper, wherever possible focus on pdf only
› Shipment by cargo ship to reduce CO2 footprint

CryoCube® F570 series

Features

  • Volume: 570 L, e.g. up to 40,000 samples
  • Efficient insulation, composed of traditional insulation, vacuum insulation panels, and Vacupor® NT technology achieve energy savings
  • Efficient compressor control system reduces cycle times to lower energy consumption and increases freezer longevity
  • New automatic vent port on front door of upright CryoCube models improves energy consumption and enables fast sample access
  • Lockable main switch to prevent switch-offs by accident
  • Location for chart recorder for data documentation
  • Ergonomic door handle of CryoCube models based on Eppendorf PhysioCare Concept® requires less force and provides easier access
  • Air-cooled as well as water-cooled versions for further energy saving
  • Full stainless steel interior for easy cleaning during maintenance and defrost cycles; powder-coated steel exterior

Applications

  • ULT freezers are suitable for storage and preservation of all types of biological materials/samples:
  • › Bacteria
  • › Cells
  • › Spores
  • › Pollens
  • › Protozoa
  • › Blood components
  • › DNA
  • › Tissue used in research only
  • › Preservation of chemicals or material testing components for a longer period of time